Page 16 - 國郁企業股份有限公司 | KUOYUH W.L.Enterprise Co.,Ltd
P. 16
R
94N Series Breaker-switch
•Technical data
•Current rating range 3~16A
•Input voltage rating 125/250VAC; 50VDC
•Interrupting Capacity 125/250VAC x 1,000A(UL 1077)
•Breakering Capacity 6 times rated current
•Dielectric Strength > 1.500VAC/min.
•Insulation Resistance >100MOHM (DC 500V)
•Degree of protection Terminal area IP00, operating area IP40
•Mechanical/Environmental Data
•Operating Ambient Temperature: -10 to +60℃ ℃
•Termination: 250’’(6.35mm)quick connects or solder terminals
•Compliance with Rohs
The product accords with the requirement of ROHS( 2011/65/EU)
94N Series
Contacts use Exempted item of RoHS Directive 2010/571/EU 8(a)
XXA
•Compliance with REACH, PAHS, PH1, PH2, PH3
•Typical applications
Tarnsforms, Motors, Battery chargers, Power supplies,
appliances, extra low voltage systems, machinery.
•Calibration(at25 )℃ •94N Series 3~16A Trip Time Curves
1000%
•100% of Rated Current: Hold , No Trip OVERLOAD TRIP TIME sec
800% 1000% 0.12-0.7
•150% of Rated Current: Trip Within 1 Hour. 600% 800% 0.18-0.9
600%
0.3-1.8
•200% of Rated Current: 5-30 sec Trip 400% 0.6-4.5
300%
1.2-9.0
4.0-40.0
•300% of Rated Current: 1.5-5.0 sec Trip 500% 200% Trip in 1Hour
150%
Hold,No Trip
100%
•Approval Load Current AS Percent of Circuit Breaker Rating 400%
•Approval & File No. Rated current Rated voltage 300%
•CUL UL E155159 3-16A 125/250VAC; 50VDC 200%
•How to Order 150%
100%
94N - 15 - 1 2 1 B R S 1 0.1 1.0 TIME IN SECONDS 100 1000 10000
10
Model No. Rating Illumnated Actuator Terminal Base Actuator Terminal Lamp TRIP CURVES ARE SPECIFIED OF 25°C/77°F
94N Amp Type Type Type Color Color Finish Type
•Ambient Temperature Correction Factor
3A........16A
Ambient
A=Yes,125Vac B=Yes,250Vac 1 =None temperature -10°C 0°C 10°C 25°C 35°C 40°C 50°C 60°C
Multiplication *1.20 1.00 *0.94 *0.85 *0.73 *0.68
A B factor *1.30 *1.10
The time/current characteristic curve depends on the ambient temperature prevailing. In order to
eliminate nuisance tripping. Please multiply the circuit breaker current ratings by the derating
factor shown below.
1 =0.25' Tab*5.3mm 2 =0.25' Tab*9.0mm 3 =0.25' Tab*9.0mm 4 =0.25' Tab*9.0mm Example : Normal Continuous Current = 10A
Solder Lug Solder Lug Solder Lug Quick Connects Ambient Temperature = 45°C
Multiplication Factor = 0.85
Recommended Rating= 10A/0.85=11.8A
Select the Nearest Rating = 12A
•Max.Internal Resistance •Internal connection diagram
B =Black W =White G =Gray Amp rating Max resistance
R =Red(PC) O =Orange(PC) N =Clear(PC) G =Green(PC) L =Bule(PC) 3.0 - 5.0Amp <0.225 Ohms
1 =Black(Nylon) 2 =Gray(Nylon) 3 =Red(Nylon) 4 =White(Nylon)
6.0 - 8.0Amp <0.175 Ohm 3 2 1
S =Plate with Tin N=Plate with Nickel 0=None
9.0 - 12.0Amp <0.125 Ohm
0 =None 1 =Red Neon Lamp 2 =Green Neon Lamp 3 =Bule Neon Lamp A=LED Lamp
13.0 - 16.0Amp <0.050 Ohm
* The specification subject to change without notice. The drawing is for reference only.
KUOYUH W.L. Enterprise Co.,Ltd.
KUOYUH W.L. Enterprise Co.,Ltd.
No.17 Kejia 6th Road Douliu City YunLin Hsien 64057 Taiwan R.O.C
http//www.kuoyuh.com.tw sales@kuoyuh.com 國郁企業股份有限公司
64057 雲林縣斗六市科加六路17號
Taiwan Tel: 886 5 551 3222 Fax: 886 5 551 3030
China Tel: 86 769 8366 6388 Fax: 86 769 8366 6362
Issue:A0 P15
Date:2017.02.20